NX-3500 Real Silent Power Supply 350Watt Special Edition

Product Description

|
|
The Nexus NX-3500 Special
Edition is the latest edition to the Nexus Real Silent power supply
series. The Nexus NX-3500 Special Edition is equipped with a large
12 cm fan which provides sufficient airflow to cool the power supply
at very low speed and at a very low noise level. This power supply
configuration produces only 19.2 dB(A) in idle mode and will be
inaudible when mounted in a computer system as the fan will be
located on the inside of the computer case. The NX-3500 has longer
power cables and is SATA ready! |
|
| Retail
box: |
 |
|
| Features: |
-
Real silent power
supply, only 19.2 dB(A) in idle mode
-
Real silent large 12
cm orange fan
-
High efficiency, Excellent
air flow
-
Output over voltage
protection
-
Short circuit protection
on all output
-
Reset Table power
shut down
-
Approved by: TÜV,
CSA, UL, NEMKO, FCC, C-tick, BSMI, CE
-
100% burn-in under
high ambient temperature (50oC)
-
Vacuum-impregnated
transformer
-
MTBF: 100K hours
at 25oC
-
100% Hi-pot tested
-
Line input fuse protection
-
Longer power cables
-
SATA ready!
|
|
| Specifications: |
-
Remote ON/OFF
Control: The power supply shall accept a logic open collector
level which will disable/enable all out put voltage (excluding
+5V standby)
-
Output voltage
hold-up time: 10.0mS minimum: at 230V / 50 Hz.
-
Operation at no
load: The power supply will be capable of being operated
with no load on any or all outputs without damage.
-
Over voltage protection:
-
+5V : 6.5V(max.)
-
+3.3V : 4.6V(max.)
-
+12V : 15.5V(max.)
-
Over current protection:
There shall be protection from an output over-current event.
The power supply may shutdown from such an event and require
power-on restart. Testing consists of application of the listed
over-current value with maximum load on all other outputs.
Over-current test values: (maximum load)
-
+3.3V : 81A(max.)
-
+5V :
65A(max.)
-
+12V :
30A(max.)
-
Short current protection:
A short circuit at any output shall cause no damage to the
power supply nor blow the primary fuse. The power supply may
shut down in the event of a short circuit and require power-on
restart. A short circuit consists of application of a test
resistance of less then 0.05 ohms at each output with maximum
load on all outputs.
-
Output risetime: The cold-start
enable output voltage risetime of all outputs shall be measured
with maximum load on all outputs. Riseti
me
(10-90%):
-
+3.3V 20mS
(max.)
-
+5V 20mS
(max.)
-
+12V 20mS
(max.)
-
-12V 20mS
(max.)
-
-5V 20mS
(max.)
-
+5Vsv 20mS
(max.)
-
Output overshoot: No output
voltage shall overshoot or generate spikes at turn-on or turn-off,
during momentary power loss, output short, or realistic input
voltage or output load changes. Overshoot is defined as any
output that exceeds the voltage tolerance plus or minus an
additional 5%.
-
Efficiency:
Overall efficiency must be 65% min. measured at normal AC mains
voltage and frequency with maximum loads on all outputs.
-
Power good signal:
230V (full load): 100-500mS
-
Temperature range:
-
operating 0oC~50oC
-
storage -20oC~+65oC
-
Relative Humidity:
90%
-
Safety requirements: TUV,
NEMKO + CB REPORT
-
Dielectric strenght:
Primary to frame ground: 1800 Vac for 1 sec. Primary to secondary:
1800 Vac for 1 sec.
-
Insulation resistance: Primary
to secondary: 20 Meg. ohms min. Primary to frame ground: 20
Meg. ohms min.
-
Ground leakage current: The
power supply ground leakage current shall be less than 0.5mA
-
Emission requirements: The
power supply ground leakage current shall be less than 3.5mA
|
|
| Output
Characteristics: |
|
|
| |
| |
Minimum |
Normal |
Maximum |
Load REG. |
Line REG. |
Ripple & Noise |
| |
Load |
Load |
load |
| +3,3V |
0.3A |
14.0A |
21.2/28A |
±5% |
±1% |
50mV
P-P |
| +5V |
1.0A |
12.7A |
30/25.5A |
±5% |
±1% |
50mV
P-P |
| +12V |
0.2A |
4.5A |
16A |
±5% |
±1% |
120mV
P-P |
| -12V |
0.0A |
0.4A |
0.8A |
±10% |
±2% |
120mV
P-P |
| -5V |
0.0A |
0.15A |
0.3A |
±10% |
±2% |
100mV
P-P |
| +5Vsb |
0.0A |
1.0A |
2.0A |
±5% |
±1% |
50mV
P-P |
| |
|
|
|
|
|
|
- (1) +3.3V & +5V total
output not exceed 220Watt. When +3.3V is load to 28A,
the +5V maximum load is 25.5A. When +3.3V is load to
21.2A, the +5V maximum load is 30A.
- (2) +3.3V & +5V & +12V
total output not exceed 330Watt.
|
|
|
| Comparison
chart: |
|
|
 |
|
|
Take
a closer look |
| |
| Technical
drawing: |
|
|
|
 |
|
| Label: |
|
|
|
 |
|
|
|
|
| Available
upon request: |
- Acoustic noise test report
- Technical drawings
- Approval certificates
|
|
| Images: |
 |
- Nexus® NX-3500
SPECIAL EDITION
- Name: NX3500_big.gif
- Format: GIF
- Size: 766(w)x738(h) - 192 kB
-
- Nexus® NX-3500
Retail Box
- Name: NX3500_box_big.gif
- Format: GIF
- Size: 784(w)x768(h) - 174 kB
|
|
| |
|
|
|
|
 |
|
| |
IN STOCK NOW SHIPPING

please email webmaster@ultraspec.us for details.